Product Description
 
 
How does it work?
Your air conditioner or heat pump works hard during hot weather. It pulls heat out of the air inside your home and discharges it into the air outside your home Meanwhile, your water heater is toiling away generating heat for your showers, dishwashing and laundry. Why not recover some of that unused heat energy discharged by your air conditioner or heat pump and use it to heat your water? That’s exactly what a heat recovery unit does
The heat recovery unit is installed in the hot line of the heat pump’s refrigerant circuit. The hot vapor flows through a heat exchanger. The heat from the vapor is then absorbed by the water, which is circulated through the heat exchanger by a small pump. This gives you inexpensive hot water. Controls keep everything operating properly. In the summer, the heat recovery unit captures some of the heat discharged by the air conditioner, essentially giving you free hot water. You can even turn your regular water heater off -just remember to turn it back on when you’re not using your air-conditioner. low-cost heating for your water during the winter months is also available.
 
Features:
·Cooling only, heating only, hot water only,cooling+free hot water,heating+hot  water functions.

·Condensed thermal energy recovery when cooling

·Hitachi Scroll compressor,Siemens controller
·Plate type heat exchanger
 
 
·LCD display
·High and low pressure protection
·Anti-freeze protection
·auto-defrosting
 ·varied heating curve
typical application
intallation
 
 

Technical data:
HEAT PUMP LSQ08R1/CR1 LSQ10R1/CR1 LSQ08R1/CR3 LSQ10R1/CR3 LSQ13R2/CR LSQ13R1/CR LSQ15R1/CR
Heat output/Power consumption at 7/35℃ kW 8.7/2.3 11.1/3.2 8.7/2.2 11.1/2.9 13.6/4.1 14.0/3.7 16.0/4.1
Heat output/Power consumption at 7/45℃ kW 8.5/2.7 10.9/3.7 8.5/2.6 10.9/3.4 13.2/4.7 13.6/4.3 15.6/4.9
Heat output/Power consumption at 7/55℃ kW 8.3/3.2 10.7/4.6 8.3/3.1 10.7/4.2 12.8/6.0 13.2/5.5 15/6.2
Heat output/Power consumption at 2/35℃ kW 7.6/2.2 9.7/3.3 7.6/2.1 9.7/2.9 11.6/4.0 12/3.6 13.4/4.1
Heat output/Power consumption at 2/45℃ kW 7.5/2.7 9.6/4.5 7.5/2.6 9.6/4.1 11.4/4.6 11.8/4.2 13.2/4.9
Heat output/Power consumption at -7/35℃ kW 5.7/2.1 7.3/3.0 5.7/2.0 7.3/2.6 8.7/3.9 9.0/3.5 10.4/4.0
Heat output/Power consumption at -7/45℃ kW 5.6/2.6 7.2/3.4 5.6/2.5 7.2/3.1 8.6/4.5 8.9/4.1 10.2/4.7
Cool output/Power consumption at 35/7℃ kW 8/2.8 9.8/3.45 8/2.6 9.8/3.25 12.6/4.6 13.0/4.2 15.0/5.3
Hot water output from 20℃ to 50℃ l/h 300 370 300 370 480 480 560
Starting current A 25 36 40 48
Soft-start relay option - - - -
Power 230V/1PH/50Hz 380V/3PH/50Hz 230V/1PH/50Hz 380V/3PH/50Hz
Compressor Scroll 2×Rotary 1×Scroll
Condenser Brazed plate heat exchanger
Nominal flow heating medium l/s 0.42 0.52 0.42 0.52 0.65 0.65 0.75
Internal pressure drop at nominal flow kPa 7 12 7 12 18 18 24
Air flow m3/h 3000 3000 3000 3000 5000 5000 5000
Nominal fan output W 220 220 220 220 140 140 140
Max outgoing heating medium temperature ℃ 58
Dimensions(HxWxD) mm 1050x1000x450 1075x1105x505
Pipe connector DN25
Weight kg 115 120 115 120 180 175 175


HEAT PUMP LSQ20R2/R LSQ25R2/R LSQ31R2/R
Heat output/Power consumption at 7/35℃ kW 22.2/5.8 28.0/7.6 32.0/8.4
Heat output/Power consumption at 7/45℃ kW 21.8/6.8 27.2/8.8 31.2/10.0
Heat output/Power consumption at 7/55℃ kW 21.0/8.8 26.4/11.2 30.0/12.6
Heat output/Power consumption at 2/35℃ kW 19.0/5.8 24/7.4 26.8/8.4
Heat output/Power consumption at 2/45℃ kW 18.8/6.8 23.6/8.6 26.4/10.0
Heat output/Power consumption at -7/35℃ kW 14.6/5.2 18.0/7.2 20.8/8.2
Heat output/Power consumption at -7/45℃ kW 14.4/6.6 17.8/8.4 20.4/9.6
Cool output/Power consumption at 35/7℃ kW 20.0/6.6 25.0/8.6 31.0/10.8
Hot water output from 20℃ to 50℃ l/h 740 950 1100
Power 380V/3PH/50Hz
Compressor 2×Scroll 2×Scroll 2×Scroll
Condenser Brazed plate heat exchanger
Nominal flow heating medium l/s 1.04 1.3 1.5
Internal pressure drop at nominal flow kPa 27 25 24
Air flow m3/h 6000 10000 10000
Nominal fan output W 440 820 820
Max outgoing heating medium temperature ℃ 58℃
Width mm 1300 1300 1300
Depth mm 690 690 690
Height mm 1050 1325 1325
Pipe connector DN40 DN40 DN40
Weight kg 270 280 310
Product Image
Select Image
Air source heat pump and chiller with hot water
Air source heat pump and chiller with hot water
Air source heat pump and chiller with hot water
Air source heat pump and chiller with hot water
Related Products
high temperature air source heat pump
high temperature air source heat pump
Air cooled chiller/heat pump with modular design
Air cooled chiller/heat pump with modular design
R410A air source heat pump heating only
R410A air source heat pump heating only
air cooled chiller/heat pump
air cooled chiller/heat pump

Powered by DIYTrade.com